Fronius Inverter Error STATE Codes

Fronius is a well-known manufacturer of solar inverters, and their inverters are widely used in Australia. Fronius inverters have a comprehensive set of error codes, called STATE codes, that indicate specific issues or conditions that may arise during the operation of the inverter.

Each code represents a specific condition or fault, and the troubleshooting steps may vary depending on the code and the specific model of the inverter. If you encounter an error code on your Fronius inverter, it is recommended to consult the inverter's user manual or contact a qualified solar technician to diagnose and resolve the issue accurately.

Most times your Fronius inverter will give you error messages so you can tell what is going on.  Here is a comprehensive list of all the error codes on Fronius IG inverters.

Fronius Fault codes Starting with 1xx

Code
Description
Possible causes
Sequence

STATE 101

Grid voltage beyond permitted limits

1. Mains voltage error
2. Incorrect values in the service menu
3. Internal fault

1. Check grid voltage, check circuit breakers are ON
2. Change values in the service menu
3. If problem persists contact your Fronius Service Partner

STATE 104

Mains frequency beyond permitted limits

1. Mains frequency error
2. Incorrect values in the service menu
3. Internal fault

1. Check mains frequency, check circuit breakers are ON
2. Change values in the service menu
3. If problem persists contact your Fronius Service Partner

STATE 107

Synchronisation with the public mains supply not possible

1. Mains not connected
2. Incorrect values in the service menu
3. Internal fault

1. Connect mains power, check circuit breakers are ON
2. Check values in the service menu
3. If problem persists contact your Fronius Service Partner

STATE 108

Islanding detected

1. Islanding detected
2. Severe disturbances in public mains
3. Internal fault

1. Automatic correction
2. Automatic correction
3. If problem persists contact your Fronius Service Partner

Fronius Fault codes Starting with 2xx

Code
Description
Possible causes
Sequence

STATE 201

Grid voltage is higher than the specified limit

1. Grid voltage error on the public mains
2. Internal fault

1. Check grid voltage
2. If problem persists contact your Fronius Service Partner

STATE 202

Grid voltage is lower than the specified limit

STATE 203

Grid frequency is higher than the specified limit

1. Grid frequency error on the public mains
2. Internal fault

1. Check grid frequency
2. If problem persists contact your Fronius Service Partner

STATE 204

Grid frequency is lower than the specified limit

STATE 205

Change of public mains impedance

1. Serious disturbances on the public mains
2. Internal fault

1. Reinforce mains cables
2. Connect Fronius IG inverter to another phase
3. If problem persists contact your Fronius Service Partner

STATE 206

Absolute value of the impedance is too high

1. Mains impedance too high
2. Internal fault

STATE 207

Mains relay does not open in spite of switch off signal

Internal fault

If problem persists contact your Fronius Service Partner

STATE 208

Mains relay does not close in spite of switch on signal

Fronius Fault codes Starting with 3xx

Code
Description
Possible causes
Sequence

STATE 301

The safety circuit detects a current peak and indicates on the mains supply

1. Voltage drop on in the public mains

2. Internal failures

1. Automatic correction and maintenance

2. If the problem persists you may contact your Fronius Service Partner

STATE 302

Grid voltage is lower than the specified limit

1. Voltage drop on in the public mains

2. Internal failures

1. Automatic correction and maintenance

2. If the problem persists you may contact your Fronius Service Partner

STATE 303

The temperature of the heat sink indicates too high on the DC-AC board

1. Ventilation slot is overfull 

2. Very high atmospheric temperature

3. Distance between inverters are short

4. Internal fault


1. Free the ventilation slot to make some space

2. Change the location of the inverter

3. Increase distance between inverters

4. If the problem persists contact your Fronius Service Partner


STATE 304

The temperature of the heat sink indicates too high on the DC-AC board

STATE 305

The feed-in process is not possible, even though the public mains parameter are within the limits

Internal problems

If the problem persists contact your Fronius Service Partner

STATE 306

POWER LOW

Intermediate circuit voltage has dropped below the prescribed threshold value for feed-in

1. Check the panels correctly
2. Internal issues


STATE 307

DC LOW

1. The DC-input voltage is too low for feed-in

2. Internal fault

STATE 308

The Intermediate circuit voltage is out of the maximum limit

1. Public mains consist of disturbances

2. Internal fault

1. Reinforce the mains cable and check

2. If the problem persists contact your Fronius Service Partner

Fronius Fault codes Starting with 4xx

Code
Description
Possible causes
Sequence

STATE 401

Communication errors between the IG control and the DC-DC board

Internal problem and mistakes

If the problem persists contact your Fronius Service Partner

STATE 402

Write the access to the internal Fronius IG memory that failed




STATE 403

The area in the internal memory for the country setting is incomplete



STATE 404

The connection between the control unit and the ENS is faulty

1. Public mains not connected properly

2. Internal fault

1. Check the public mains

2.If the problem still continues to persists contact your Fronius Service Partner

STATE 405

An old or incorrect version of the ENS microprocessors has been recognized

Internal defects

If the problem persists contact your Fronius Service Partner

STATE 406

The temperature sensor is not connected properly and the DC-AC board consist of any fault



STATE 407

Temperature sensor on the DC-DC board faulty or not connected



STATE 408

Public mains seem to be unsynchronized or any other fault detected

1. Public mains causing disturbances

2. Internal fault

1. Error is settled down automatically

2. If the problem persists contact your Fronius Service Partner

STATE 409

Supply of the DC-AC board is not available

Internal disconnections or faults





If the problem persists contact your Fronius Service Partner






STATE 410

The service plug which is present on the DC-AC board is not set correctly and appropriately

STATE 412

The value for fixed voltage is set at a higher range than the open-circuit voltage of the PV generator

STATE 413

Open circuit voltage is too high at the moment of transformer switching

STATE 414

The Memory array for Fronius IG type in the EE-PROM is at fault

1. One-off – memory having errors

2. Internal fault

1. Error is corrected automatically

2. If the problem persists contact your Fronius Service Partner

STATE 415

No END-enabling signal is detected despite the release by IG-control

Internal fault

If the problem persists contact your Fronius Service Partner

STATE 416

Communication error between IG-Control and the power stack

1. One-off – communication error

2. Internal fault

1. Error is remedied automatically

2. If the problem persists contact your Fronius Service Partner

STATE 417

Hardware ID-collision means internal error within the inverter

Internal fault

If the problem persists contact your Fronius Service Partner

STATE 419

Two or more power stacks having the same number set and with identical Unique ID

Internal fault



If the problem persists contact your Fronius Service Partner




STATE 420

Incomplete number of power stacks detected after reaching the online threshold according to the device type

STATE 421

Hardware ID sequence error

STATE 425

Receive the time-out for data exchange with one or more power stacks has been exceeded

1. One-off error 

2. Internal fault

1. Automatic correction

2. If the problem persists contact your Fronius Service Partner


STATE 431

All power stacks are in the boot mode

Internal fault

If the problem persists contact your Fronius Service Partner

STATE 432

Consistent error in the power stack management

1. One-off error

2. Internal fault

1. Automatic correction

2.If the problem persists contact your Fronius Service Partner

STATE 416

Communication error between IG-Control and the power stack

1. One-off – communication error

2. Internal fault

1. Error is remedied automatically

2. If the problem persists contact your Fronius Service Partner

STATE 433

Allocation of the error caused due to dynamic addresses

1. One-off error

2. Internal fault

1. Automatic correction

2.If the problem persists contact your Fronius Service Partner

STATE 434

Ground-level fault detected

1. One-off error

2. Internal fault





1. Automatic correction

2.If the problem persists contact your Fronius Service Partner





STATE 435

Wrong configuration setting for EE-Prom

STATE 436

Error transmission faults occured

STATE 437

Power stack workaround is active

STATE 438

Error during the state code transmission

1. One-off error

2. Permanent error occurred

1.An Automatic correction can resolve the issue

2.If the problem persists contact your Fronius Service Partner

STATE 441

Power rack fan faults

Internal fault

If the problem persists contact your Fronius Service Partner

STATE 442

Master for one phase could not be assigned further

1. Temporary communication errors 2. Internal fault

1. Error is solved automatically without external solutions

2. If the problem persists contact your Fronius Service Partner

STATE 443

The DC-DC energy transfer failures

1. Error occurred while switching on a power stack 2. Internal fault

1. Error is rectified automatically

2. If the problem persists contact your Fronius Service Partner

STATE 444

AC monitoring self-test is interrupted

During the self-test, another error occured

Simply Quit the self-test by pressing ESC and solve the failure according to the error as in the code list

Fronius Fault codes Starting with 5xx

Code
Description
Possible causes
Sequence

STATE 501

Heat sink temperature raise too high, although the Fronius IG is still on low output

1. Ventilation slot gets congested

2. Internal sequence has some fault

1. Free the ventilation slot to make some space

2.If the problem persists contact your Fronius Service Partner

STATE 502

An isolation fault occurred between DC+ or DC- to earth and has been detected as well

Isolation fault at the solar generator

Check all the cables and solar generator properly

STATE 505

The area that is in the internal memory for the “Setup” values, is incomplete

1. One-off error

2. Internal fault





1. Automatic correction

2.If the certain problem persists contact your Fronius Service Partner




STATE 506

The area of the internal memory meant for the “Total” values is incomplete

STATE 507

The area in the internal memory mentioned for the “Day/Year” values is incomplete

STATE 508

The area in the internal memory consists the “WR number” is damaged

STATE 510

Errors detected by LocalNet or the self-diagnostic system

1. One-off memory error

2. Internal fault


1. Automatic correction

2. If the problem persists contact your Fronius Service Partner




STATE 511

Errors detected by LocalNet Sensor Card self-diagnostic system

STATE 512

There are too many stacks that have been detected relating to the device type

1. One-off error

2. Internal fault


STATE 513

Power stacks in the boot mode

STATE 514

An Incomplete number of power stacks have been detected after reaching  the online threshold – Device type

During the self-test, another error occured

Simply Quit the self-test by pressing ESC and solve the failure according to the error as in the code list

STATE 515

One or more power stacks notified in STATE 406/ 407/ 409/ 410

Internal fault



If problem persists contact your Fronius Service

STATE 516

One power stack that exceeds the permitted limit of error messages per day (>50x)

Partner


STATE 517

Permanent POWER LOW or the DC LOW error